DCO Electrical Engineering · Services
Data centre construction for reliable business infrastructure
DCO Electrical Engineering supports your business with tailored data centre construction, power racks, cooling systems, monitoring systems, and fire protection. You benefit from an approach spanning consultancy and planning to execution and maintenance, aligned with your existing infrastructure and business operations.

At a glance
What does DCO Electrical Engineering do for you in terms of data centre construction?
DCO Electrical Engineering provides tailored data centre construction, power racks, cooling systems, monitoring systems, and fire protection for businesses and industry. Execution is tailored to your electrical load, building, operational use, and safety requirements. With 25 years of experience, we support you from preparation and installation through to inspection and maintenance. You can count on services throughout Belgium and 24/7 support.
- Target group
- Businesses and industry; private individuals where relevant
- Operating area
- Throughout Belgium · Fabrieksstraat 108, 1930 Zaventem
- Support
- 24/7 support · 25 years of experience
- Standards/Safety
- VCA-certified; applicable AREI and safety regulations according to the installation
Data centre construction · 1
Data centre construction tailored to your business processes
A data centre is designed around the services that must remain available. We discuss IT load, expansion capacity, maintenance, and the consequences of downtime before decisions are finalised. An integrated approach connects electrical engineering with the layout of the space. Performance, energy efficiency, and safety each have their place in the design. Redundancy is thereby a deliberate design choice, not an automatic feature of every technical room.
For data centre construction tailored to your business processes, we determine the scope prior to execution. You discuss with us the existing situation, the desired operation, and the conditions for site access. This allows material selection, scheduling, and any potential interruptions to be coordinated.
- Preparation based on your building and operational use.
- Coordination of execution, inspection, and maintenance.
At DCO Electrical Engineering, we specialise in designing, building, and maintaining data centres that meet the most stringent requirements regarding reliability, efficiency, and safety. We offer bespoke data centre construction, delivering solutions that align with the specific requirements of your organisation. From data centre design to the installation of power supply, cooling, monitoring, and security, we provide a comprehensive approach.
Data centre construction · 2
Power racks and electrical distribution
Power racks for data centres require an appropriate power supply and a clear distribution setup to the equipment. We examine power ratings per rack, connections, and potential expansion. UPS and PDU systems are matched to the desired continuity and connected load. Where segregated supply paths are required, we assess the entire chain. After all, two connections to the same single point of failure do not automatically result in an independent power supply.
For power racks and electrical distribution, we determine the scope prior to execution. You discuss with us the existing situation, the desired operation, and the conditions for site access. This allows material selection, scheduling, and any potential interruptions to be coordinated.
- Preparation based on your building and operational use.
- Coordination of execution, inspection, and maintenance.
A properly functioning data centre is essential for your business continuity. That is why at DCO Electrical Engineering we ensure an integrated approach to the construction and fit-out of your data centre, striving for a perfect balance between performance, energy efficiency, and safety. Our specialist electricians work closely with you, from the design phase to final delivery, to create a data centre electrical installation that meets all your business requirements.
Data centre construction · 3
Cooling systems and energy-efficient fit-out
Cooling systems for data centres must be able to dissipate heat from your IT equipment. We align the technical fit-out with the expected load and rack positioning. Airflows, maintenance access, and the impact of future expansion are discussed in advance. The electrical power consumption of cooling is factored into the overall design. This prevents a scenario where sufficient server capacity is available, but the supporting infrastructure is inadequate for actual operational use.
For cooling systems and energy-efficient fit-out, we determine the scope prior to execution. You discuss with us the existing situation, the desired operation, and the conditions for site access. This allows material selection, scheduling, and any potential interruptions to be coordinated.
- Preparation based on your building and operational use.
- Coordination of execution, inspection, and maintenance.
Data centre construction · 4
Monitoring systems with actionable alerts
Monitoring systems for data centres highlight anomalies before you have to rely solely on user reports. We discuss what data is meaningful, such as load, temperature, and power supply status. Thresholds and notification routes are aligned with your management organisation. An alarm is only useful if it is clear who responds and which actions are safe to take. Therefore, user instructions and a tested escalation chain are part of commissioning monitoring systems.
For monitoring systems with actionable alerts, we determine the scope prior to execution. You discuss with us the existing situation, the desired operation, and the conditions for site access. This allows material selection, scheduling, and any potential interruptions to be coordinated.
- Preparation based on your building and operational use.
- Coordination of execution, inspection, and maintenance.
Data centre construction · 5
Fire protection, testing, and support
Fire protection for data centres requires coordination with the space, the equipment present, and the safety concept. Fire detection in collaboration with BEMAC can form part of this. Required interfaces and responsibilities are discussed in advance with the parties involved. We evaluate testing and maintenance schedules in relation to your business continuity. An N+1 concept or other availability target is only stated when the specific design and underlying components support it.
For fire protection, testing, and support, we determine the scope prior to execution. You discuss with us the existing situation, the desired operation, and the conditions for site access. This allows material selection, scheduling, and any potential interruptions to be coordinated.
- Preparation based on your building and operational use.
- Coordination of execution, inspection, and maintenance.
Additional points of attention within your project
- Data centre construction
- Bespoke data centre construction
- Power racks for data centres
- Cooling systems for data centres
- Data centre-related installations we carry out for businesses and industry
- Monitoring systems for data centres
- Fire protection for data centres
DCO Electrical Engineering is located at Fabrieksstraat 108, 1930 Zaventem and operates throughout Belgium. You can rely on 25 years of experience, a VCA-certified organisation, and 24/7 support. As part of DCO Group, alongside DCO Bouw and DCO IT, we align electrical engineering requirements with the broader context of your building and infrastructure.
Project gallery
Photos of data centre construction by DCO Electrical Engineering
Frequently asked questions
Questions about data centre construction
Practical answers from our technicians for businesses, industry and homeowners across Belgium.
A data centre is designed around the services that must remain available. We discuss IT load, expansion capacity, maintenance, and the consequences of downtime before decisions are finalised. An integrated approach connects electrical engineering with the layout of the space. Performance, energy efficiency, and safety each have their place in the design. Redundancy is thereby a deliberate design choice, not an automatic feature of every technical room.

Discuss data centre construction with DCO Electrical Engineering?
Active throughout Belgium from Zaventem, with 25 years of experience and 24/7 support. Request a no-obligation quote or call us directly.